Medtronic temporary pacemaker cables. Our Pacing Systems 2019-12-20

External Temporary Pacemakers

Medtronic temporary pacemaker cables

Extrathoracic temporary epicardial pacing may provide support to these patients for up to three months at which time permanent, epicardial-pacing leads can be implanted. Extreme caution must be taken to properly ground all line-powered equipment used in the vicinity of the patient. No lead extenders, lead adaptors or abandoned leads present; no broken leads or leads with intermittent electrical contact as confirmed by lead impedance history; the device must be operating within the projected service life, and the system must be implanted in the left or right pectoral region. Medtronic cardiac devices are designed to withstand exposure to ablation energy. To verify that components are part of a SureScan system, visit. Patients with complete heart block are paced using the temporary wires for 10-14 days for their underlying rhythm to return before placing a permanent pacemaker. Do not kink, stretch, or severely bend the catheter.

Next

Our Pacing Systems

Medtronic temporary pacemaker cables

Contraindications There are no known contraindications to the use of temporary pacing as a means to control the heart rate. Dual-chamber temporary pacemakers are intended to be used in conjunction with a cardiac pacing lead system for temporary single or dual chamber pacing in a clinical environment. This setting provides at least a 2:1 safety margin. There are no known contraindications for the use of pacing as a therapeutic modality to control heart rate. Medtronic recommends use of the Model 53922 Disposable Cover to reduce the risk of tampering with the programmed parameters. The temporary epicardial leads are removed just before the patient is discharged from the intensive care unit. Electrosurgical units can cause tachyarrhythmias by inducing current on the leads.

Next

Medtronic Temporary Myocardial Pacing Leads

Medtronic temporary pacemaker cables

If you continue, you will leave this site and go to a site run by someone else. Do not use excessive force when inserting a catheter into a vessel. This value is set by the output control and does not vary. Temporary epicardial pacing can be used to bridge this interval between post operative heart block and either recovery of spontaneous conduction or placement of a permanent pacemaker. Improper connection, and displacement or fracture of leads or cables may result in pacemaker system failure. Complications related to the use of temporary external pacemakers include, but are not limited to asystole following abrupt cessation of pacing, inhibition, and reversion.

Next

MEDTRONIC 5348 TECHNICAL MANUAL Pdf Download.

Medtronic temporary pacemaker cables

Potential Complications Potential patient-related complications related to the use of endocardial leads include, but are not limited to, valve damage, fibrillation and other arrhythmias, thrombosis, thrombolytic and air embolism, cardiac perforation, heart wall rupture, cardiac tamponade, muscle or nerve stimulation, pericardial rub, infection, myocardial irritability, and pneumothorax. Although more reliable than the transcutaneous patches, there is a risk of lead dislodgement and ventricular perforation Transesophageal pacing is used for brief bursts to overdrive the atrium in order to terminate atrial tachycardias. Contraindications There are no known contraindications to the use of temporary pacing as a means to control the heart rate. Your use of the other site is subject to the terms of use and privacy statement on that site. The stimulation may be controlled by repositioning or replacing the electrode, or by reducing the output pulse amplitude.

Next

Temporary External Pacemakers

Medtronic temporary pacemaker cables

Dual chamber sequential pacing is contraindicated in patients with chronic or persistent supraventricular tachycardias, including atrial fibrillation or flutter. Therefore, ventricular or single-chamber pacing alone does not always result in optimal cardiac output. The content may not be approved for use in your specific region or country. Complication related to inhibition or reversion of the pacemaker in the presence of strong electromagnetic interference. Depending on the pacing mode, a subset of pacing parameters is displayed. Potential lead complications include, but are not limited to, valve damage, fibrillation, thrombosis, thrombotic and air embolism, cardiac perforation, heart wall rupture, cardiac tamponade, pericardial rub, infection, myocardial irritability, and pneumothorax.

Next

External Pacemakers

Medtronic temporary pacemaker cables

Clean and sterilize them before each use. When the temporary pacemaker turns on, the following occurs: a self-test is initiated. Dispose of this product according to local regulations. Atrial high-rate burst pacing therapy is intended for use in the atrium only. The temporary pacemaker must be used in an environment where the patient is monitored continuously to ensure that it is operating properly and delivering appropriate therapy to the patient.

Next

Medtronic Temporary Myocardial Pacing Leads

Medtronic temporary pacemaker cables

Asynchronous pacing is contraindicated in the presence or likelihood of competition between paced and intrinsic rhythms. Brief Statement: Temporary Pacemakers Model 5348 and Model 5388 Indications Single-chamber temporary pacemakers are designed to be used in conjunction with a cardiac pacing lead system for temporary atrial or ventricular pacing in the clinical environment. High-rate burst therapy is intended for use in the atrium only. Do not place transthoracic defibrillation paddles directly over the device. Brief Statement: Model 5392 Dual-Chamber Temporary Pacemaker Intended Use The Medtronic Model 5392 Dual-Chamber Temporary pacemaker is intended to be used in conjunction with a cardiac pacing lead system for temporary single or dual chamber pacing in a clinical environment by trained personnel. If removal of the device is required, it is recommended that the removal be performed by a clinician who has expertise in the removal of implanted leads.

Next

MEDTRONIC 5348 TECHNICAL MANUAL Pdf Download.

Medtronic temporary pacemaker cables

For the SelectSecure Model 3830 lead, total patient exposure to beclomethasone 17,21-dipropionate should be considered when implanting multiple leads. Dual chamber sequential pacing is contraindicated in patients with chronic or persistent supraventricular tachycardias, including atrial fibrillation or flutter. Bipolar Coaxial 6495 Bipolar Temporary Myocardial Pacing Lead The Medtronic Model 6495 Bipolar Coaxial Temporary Pacing Lead is designed to provide the advantages of bipolar technology based on the sensing and pacing capabilities of the Medtronic Model 6500 Unipolar Temporary Pacing Lead. This can result in a large current flowing through the implanted lead system and temporary pacemaker, which could reduce intended defibrillation energy delivered to the patient or cause myocardial damage. The recording is done by connecting the atrial pacemaker wires to the left and right arm leads.

Next

MEDTRONIC 5392 TECHNICAL MANUAL Pdf Download.

Medtronic temporary pacemaker cables

Potential Adverse Events or Potential Complications Air embolism, allergic reaction to contrast media, arteriovenous fistula formation, bleeding at the insertion site, brachial plexus injury, cardiac tamponade, dislodgement, dissection, endocarditis, heart block, hematoma formation, hemothorax, infection, irregular heart beat, mediastinal widening, perforation, pneumothorax, subclavian artery puncture, thrombophlebitis, thrombosis, valve damage, vascular occlusion, vessel damage. Connecting the pacing lead system to the patient cable receptacles Refer to the applicable patient cable technical manual for more information. Operational failure of the temporary pacemaker can occur as the result of battery depletion, mishandling, or random component failure. Whenever possible, for the safety of the patient, disconnect the temporary pacemaker from the implanted lead system before defibrillating or cardioverting. All other trademarks are the property of their respective owners. The atrial wires are placed on the right atrium. Do not modify the temporary pacemaker.